Sports Lighting Controller

Illuminator 2

A standalone sports lighting controller for councils and clubs. Authorised users activate field lighting with secure PINs sent by SMS or entered on a keypad - no app, no subscription, no infrastructure replacement. Standard electrician installation.

Illuminator 2 sports lighting controller

Key Features

Self-Serve Access

Authorised users activate lighting with secure PINs sent by SMS or entered on an optional keypad - from any phone, any time.

Automatic Usage Logging

Every session is logged and emailed automatically as a CSV report. No manual record-keeping required.

Smart Curfew Timers

Configurable access windows prevent unauthorised or late-night use without any manual intervention.

Multi-Field Support

Up to 8 individually configurable outputs per device for separate fields, courts, or lighting circuits.

Works with Existing Infrastructure

Compatible with both HID and LED lighting systems. No rewiring - standard electrician installation.

Australian Made

Built locally and supported by over 25 years of field instrumentation experience.

How It Works

Mount on Board

The Illuminator 2 mounts directly onto your existing distribution board. Standard electrician installation - no new infrastructure required.

Configure via Browser

Set up users, PINs, schedules, and curfew timers from any web browser on your LAN or Wi-Fi. No software or licences required.

Automated Logging & Reports

Usage is recorded automatically and emailed as a CSV report on your chosen schedule - ready for billing or compliance.

Users Activate by PIN

Authorised users send their PIN via SMS or enter it on a keypad. Lighting activates and switches off automatically at session end.

Multi-Site Management

Illuminator Central

A centralised dashboard for councils and facility managers. Remotely configure schedules, automate access windows, and view consolidated usage and billing reports across all your sites from one interface.

Simplify Your Sports Lighting

Contact us to discuss your facility's requirements, request a quote, or arrange a demonstration.

Inputs & Outputs

Inputs
Integrated Inputs 8 × digital or analogue (voltage-free contacts, switches, pulse, 4–20 mA, 0–2.5 V, common ground)
System Internal temperature, charger state, battery voltage
Outputs
Total 8 outputs
Type Normally open relay contacts (1 A @ 30 V DC, resistive load)
Activation SMS, keypad, timer, or browser interface

Communications & Logging

Communication Interfaces
Ethernet 10/100 base-T RJ-45
Mobile 4G (optional)
Wi-Fi Optional
Antenna Dual external
Logger
Capacity ~100,000 records
Storage Battery backed RAM
Download Format CSV file
Reporting FTP, FTPS, SMTP (scheduled email)

General

Physical
Size 110mm (W) × 200mm (H) × 85mm (D)
Weight ~800g
IP Rating IP20
Operating Temp -5°C to +50°C
Warranty 12-month manufacturer's warranty
Power
Input 16–30V DC
Input Current <120mA
Battery External 12V sealed lead-acid
Source Mains charger or solar panel